PAC10 Subscriber unit, 10 channels, ATC interface

PAC10

Applications

Provides connection to Exchange for 10 remote subscribers (phones), via access multiplexers (exchange side)

Technical data

  • Impedance 600 Ω
  • Relative levels
    • Output –4 dBr± 3dB (in 0.1 dB steps)
    • Input –3 dBr± 3dB (in 0.1 dB steps)
  • Loop current ≤ 60 mA
  • Loop resistance ≤ 350 Ω
  • Ringing load impedance> 1 kΩ + 0,47μF
  • Ringing detection level 15 up to 35 Veff /25 Hz
  • Maximum ringing voltage 90 Veff
  • Ringing frequency 16 up to 50 Hz
  • Metering
    • Frequency (standard/option) 16/12 kHz ± 1%
    • Sensitivity level 85 mV

Data sheets (pdf): FM2x2 (English), FM MSAN (English)